Overview

Real time clock (RTC) is a computer clock (most often in the form of an integrated circuit) that keeps track of the current time. RTCs are present in almost any electronic device which needs to keep accurate time. More general information here.

IGEP Boards have two RTC clocks, each one located at MPU and PMIC:

  • RTC System clock: system clock is controlled by MPU using its internal RTC peripheral. Every boot-up, the default firmware (/etc/init.d/hwclock.sh) copies the hardware clock data from /dev/rtc to system clock data to keeps clock up to date.
  • RTC Hardware clock: hardware clock is controlled by PMIC using its internal RTC peripheral. RTC PMIC affords two behaviours:
    • RTC battery is not used: PMIC RTC peripheral keeps hardware clock alive when OS isn't running and power source is active. If the power source fails, the PMIC RTC peripheral will lose its clock.
    • RTC battery is used: PMIC RTC peripheral keeps hardware clock alive when OS isn't running and backup battery powers the backup state as far as the input voltage is high enough.

Simplified RTC diagram

Block diagram from IGEP0033

Requirements

This How-to has been tested with an IGEPv2 RC Board (DM3730 and TPS65950), steps used below can be slightly different for other boards:

Rectify clock drift

IGEP Boards use as a source clock an external 32,768 kHz crystal. This passive component can add clock drifts due:

  • General drift error
  • Ambient temperature drift error
  • Aging drift error
  • ...

Software tools can be used to compensate these errors. Once you tested your implementation add some rule to cron deamon to automatize the process. Some available solutions are:

Set the date and time via NTP

If your board its is connected to Internet, this can be the most interesting workaround. The network time protocol (NTP) is the current widely accepted standard for synchronizing clocks over the Internet. NTP uses a hierarchical scheme in order to synchronize the clocks in the network.

ntpdate program

Ntpdate program is not installed into firmware by default, use zypper program to download and install the package:

  • Uninstall ntp deamon:
zypper rm ntp
  • Install ntpdate
zypper in ntpdate

Once you finished it, make sure that IGEP is connected to Internet.

  • Synchronize system clock and hardware clock with NTP server:
ntpdate pool.ntp.org; hwclock --systohc 
  • Compare offset between ntp server and your system clock:
ntpdate -q pool.ntp.org && date 

If the result is positive, it means that your system clock is delayed and viceversa.

ntpd deamon

Igep community logo.png This is a work in progress article. Help other developers like you in the IGEP Community by improving it!

Rectify systematic error editing PMIC RTC registers

This workaround can be helpful when your board is not connected to Internet all the time. For this method we are going to:

  • Calculate systematic clock error
  • Rectify systematic clock error configuring PMIC RTC registers

Calculate systematic clock error

Each IGEP Board has its own systematic clock error. To guess it, Can be helpful use ntpdate program to calculate systematic clock error added every day:

  • Synchronize your system clock using: ntpdate pool.ntp.org
  • Compare actual offset (it is recommendable wait between one or two days to deprecate random errors produced by crystal and ntp synchronization): ntpdate -q pool.ntp.org && date

Finally, my IGEPv2 RC Board was a systematic drift of +3.6 seconds/day aprox.

Rectify systematic clock error configuring PMIC RTC registers

Overview

Now its time to compensated this delayed drift (+3.6 seconds/day) configuring PMIC RTC registers. The edited registers will be:

  • RTC_CTRL_REG: Enables RTC compensation.
    • I2c bus: I2C1
    • Address: 0x4b
    • Register: 0x29
  • RTC_COMP_LSB_REG: Less significant bit of drift value (COM_REG) in 16 bit (Two's complement).
    • I2c bus: I2C1
    • Address: 0x4b
    • Register: 0x2c
  • RTC_COMP_MSB_REG: Most significant bit of drift value (COM_REG) in 16 bit (Two's complement).
    • I2c bus: I2C1
    • Address: 0x4b
    • Register: 0x2d

Calculate COM_REG value

If RTC_CTRL_REG PMIC RTC peripheral compensates every hour and 1 second the clock drift using the COMP_REG value. Use the next formula to calculate it:

Rtc formula.gif

Now pass your COMP_REG decimal value to 16 bit hexadecimal, in my case was 0X1333. COMP_REG will be added to the RTC 32-kHz counter, the duration of the current second becomes [(32,768 – COMP_REG)/32,768] seconds; therefore, it is possible to compensate the RTC with 1/32,768-second time unit accuracy each hour.

Edit registers

Registers will be edited using the i2c-tools, these registers will be modified until RTC source is not active:

  • Enable Hardware compensation:
 i2cset -f -y 1 0x4b 0x29 0x05 
  • Write RTC_COMP registers:
i2cset -f -y 1 0x4b 0x2d 0x13
i2cset -f -y 1 0x4b 0x2c 0x33 
  • Check register values:
i2cdump -y -f 1 0x4b 

More information at TPS65950 TRM section 3.4.2

Correct system clock

To compensate system clock using the compensated hardware clock is necessary the following command:

 hwclock --hctosys