IGEP0040HardwareRABugs

From IGEP - ISEE Wiki

Revision as of 18:39, 6 August 2015 by Pau (talk | contribs) (BUG ALL_03: PRI_TRST is low, has no PU)

Jump to: navigation, search

BUG ALL_01: (IMPORTANT) Missing 1V8 26MHz Oscillator

INFO:: This clock is not mounted at proto first assembly. It is necessary to enable some PLL and other PXA2128 clock requirements.

WORKAROUND: Installed a 1V8 26MHz Oscillator with 50 ppm from "XTAL affaire box"

- Mount O1, R106, C276

RESULT:

- Tested with oscilloscope VCXO_IN signal


BUG ALL_02: Marvell flat cable connector mounted

WORKAROUND: Use a 1.27 mm header instead to allow get access to JTAG signals easier

- Mount JTAGB

- Umount JTAG


BUG ALL_03: PRI_TRST is low, has no PU

WORKAROUND: Use PU resistor to V_1P8 to pull high this signal. This resistors should be added to IGEP0040 layout. Need to check if this bug is important


BUG ALL_04: (IMPORTANT) Remove power bad resistors

INFO:: This resistors disables power sequence from power switch and LDOs to PXA2128

WORKAROUND: Disable this SMARC feature

- Umount: R971, R972, R973, R974 and R975


BUG ALL_05: V_3P3 LDO has no delay sequence

INFO:: Need to check if this bug is important