=== J960 connector ===
Under constructionJ960 connector can not use mux capabilities, because this connector is dedicated to use RS232 comunication. Default hardware/software configuration is:<span lang="en" id="result_box"><span class="hps"></span></span><br> {| cellspacing="1" cellpadding="1" border="1" style="width: 498px; height: 381px;"|-| Pad | Connect to: | Default periphera: | Other peripheral: | Share with:<br> | Default function:<br>|-| 1 | - | - | - | -<br> | <br>|-| 2 | RS232_RX2 | UART3_RX | UART2_RX | -<br> | Kernel console params'''(4)'''<br>|-| 3 | RS232_TX2 | UART3_TX | UART2_TX | -<br> | Kernel console params'''(4)'''<br>|-| 4 | - | - | - | -<br> | -<br>|-| 5 | GND | - | - | -<br> | -<br>|-| 6 | GND | - | - | -<br> | -<br>|-| 7 | - | - | - | -<br> | -<br>|-| 8 | RS232_TX1 | UART1_TX | UART3_TX | RS485 interface'''(5)'''<br> | -<br>|-| 9 | RS232_RX1 | UART1_RX | UART3_RX | RS485 interface'''(5)'''<br> | -<br>|-| 10 | - | - | - | -<br> | -<br>|} <br> - Don't use the same peripheral in more than one pad. - Other peripherals can be configured via hardware, placing/replacing some resistances. See IGEPv2 Schematic for more information. '''(4):''' To set other functionalities to UART3 (/dev/ttyS2) edit igep.ini file: Search line: <pre>console=ttyS2,115200n8</pre> Replace by: <pre>; console=ttyS2,115200n8</pre> '''(5): '''Allows to use UART1 as RS232 instead of EI485, edit igep.ini:<br> Search line: <pre>board.ei485=yes</pre> Replace by: <pre>board.ei485=no</pre>